SMART tracking: Simultaneous anatomical imaging and real-time passive device tracking for MR-guided interventions
August 28, 2019 Β· Declared Dead Β· π Physica medica (Testo stampato)
"No code URL or promise found in abstract"
Evidence collected by the PWNC Scanner
Authors
Frank Zijlstra, Max A. Viergever, Peter R. Seevinck
arXiv ID
1908.10769
Category
physics.med-ph
Cross-listed
cs.CV
Citations
4
Venue
Physica medica (Testo stampato)
Last Checked
3 months ago
Abstract
Purpose: This study demonstrates a proof of concept of a method for simultaneous anatomical imaging and real-time (SMART) passive device tracking for MR-guided interventions. Methods: Phase Correlation template matching was combined with a fast undersampled radial multi-echo acquisition using the white marker phenomenon after the first echo. In this way, the first echo provides anatomical contrast, whereas the other echoes provide white marker contrast to allow accurate device localization using fast simulations and template matching. This approach was tested on tracking of five 0.5 mm steel markers in an agarose phantom and on insertion of an MRI-compatible 20 Gauge titanium needle in ex vivo porcine tissue. The locations of the steel markers were quantitatively compared to the marker locations as found on a CT scan of the same phantom. Results: The average pairwise error between the MRI and CT locations was 0.30 mm for tracking of stationary steel spheres and 0.29 mm during motion. Qualitative evaluation of the tracking of needle insertions showed that tracked positions were stable throughout needle insertion and retraction. Conclusions: The proposed SMART tracking method provided accurate passive tracking of devices at high framerates, inclusion of real-time anatomical scanning, and the capability of automatic slice positioning. Furthermore, the method does not require specialized hardware and could therefore be applied to track any rigid metal device that causes appreciable magnetic field distortions.
Community Contributions
Found the code? Know the venue? Think something is wrong? Let us know!
π Similar Papers
In the same crypt β physics.med-ph
R.I.P.
π»
Ghosted
R.I.P.
π»
Ghosted
Gibbs-Ringing Artifact Removal Based on Local Subvoxel-shifts
R.I.P.
π»
Ghosted
Deep Learning-enabled Virtual Histological Staining of Biological Samples
R.I.P.
π»
Ghosted
Eigenspectra optoacoustic tomography achieves quantitative blood oxygenation imaging deep in tissues
π
π
The Cartographer
Deep learning for biomedical photoacoustic imaging: A review
R.I.P.
π»
Ghosted
The reliability of a deep learning model in clinical out-of-distribution MRI data: a multicohort study
Died the same way β π» Ghosted
R.I.P.
π»
Ghosted
Neural Architecture Search with Reinforcement Learning
R.I.P.
π»
Ghosted
Federated Learning: Strategies for Improving Communication Efficiency
R.I.P.
π»
Ghosted
In-Datacenter Performance Analysis of a Tensor Processing Unit
R.I.P.
π»
Ghosted