Automated Detection of Left Ventricle in Arterial Input Function Images for Inline Perfusion Mapping using Deep Learning: A study of 15,000 Patients
October 16, 2019 Β· Declared Dead Β· + Add venue
"No code URL or promise found in abstract"
Evidence collected by the PWNC Scanner
Authors
Hui Xue, Ethan Tseng, Kristopher D Knott, Tushar Kotecha, Louise Brown, Sven Plein, Marianna Fontana, James C Moon, Peter Kellman
arXiv ID
1910.07122
Category
q-bio.QM
Cross-listed
cs.CV,
eess.IV
Citations
0
Last Checked
3 months ago
Abstract
Quantification of myocardial perfusion has the potential to improve detection of regional and global flow reduction. Significant effort has been made to automate the workflow, where one essential step is the arterial input function (AIF) extraction. Since failure here invalidates quantification, high accuracy is required. For this purpose, this study presents a robust AIF detection method using the convolutional neural net (CNN) model. CNN models were trained by assembling 25,027 scans (N=12,984 patients) from three hospitals, seven scanners. A test set of 5,721 scans (N=2,805 patients) evaluated model performance. The 2D+T AIF time series was inputted into CNN. Two variations were investigated: a) Two Classes (2CS) for background and foreground (LV mask); b) Three Classes (3CS) for background, foreground LV and RV. Final model was deployed on MR scanners via the Gadgetron InlineAI. Model loading time on MR scanner was ~340ms and applying it took ~180ms. The 3CS model successfully detect LV for 99.98% of all test cases (1 failed out of 5,721 cases). The mean Dice ratio for 3CS was 0.87+/-0.08 with 92.0% of all test cases having Dice ratio >0.75, while the 2CS model gave lower Dice of 0.82+/-0.22 (P<1e-5). Extracted AIF signals using CNN were further compared to manual ground-truth for foot-time, peak-time, first-pass duration, peak value and area-under-curve. No significant differences were found for all features (P>0.2). This study proposed, validated, and deployed a robust CNN solution to detect the LV for the extraction of the AIF signal used in fully automated perfusion flow mapping. A very large data cohort was assembled and resulting models were deployed to MR scanners for fully inline AI in clinical hospitals.
Community Contributions
Found the code? Know the venue? Think something is wrong? Let us know!
π Similar Papers
In the same crypt β q-bio.QM
R.I.P.
π»
Ghosted
R.I.P.
π»
Ghosted
DeepConv-DTI: Prediction of drug-target interactions via deep learning with convolution on protein sequences
R.I.P.
π»
Ghosted
ProtVec: A Continuous Distributed Representation of Biological Sequences
R.I.P.
π»
Ghosted
A Perspective on Deep Imaging
R.I.P.
π
404 Not Found
Deep learning in bioinformatics: introduction, application, and perspective in big data era
R.I.P.
π»
Ghosted
Data-driven Advice for Applying Machine Learning to Bioinformatics Problems
Died the same way β π» Ghosted
R.I.P.
π»
Ghosted
Federated Learning: Strategies for Improving Communication Efficiency
R.I.P.
π»
Ghosted
In-Datacenter Performance Analysis of a Tensor Processing Unit
R.I.P.
π»
Ghosted
Deep Convolutional Neural Networks for Computer-Aided Detection: CNN Architectures, Dataset Characteristics and Transfer Learning
R.I.P.
π»
Ghosted