Lumen Shape Reconstruction using a Soft Robotic Balloon Catheter and Electrical Impedance Tomography
July 25, 2022 Β· Declared Dead Β· π IEEE/RJS International Conference on Intelligent RObots and Systems
"No code URL or promise found in abstract"
Evidence collected by the PWNC Scanner
Authors
James Avery, Mark Runciman, Cristina Fiani, Elena Monfort Sanchez, Saina Akhond, Zhuang Liu, Kirill Aristovich, George Mylonas
arXiv ID
2207.12536
Category
cs.RO: Robotics
Citations
2
Venue
IEEE/RJS International Conference on Intelligent RObots and Systems
Last Checked
4 months ago
Abstract
Incorrectly sized balloon catheters can lead to increased post-surgical complications, yet even with preoperative imaging, correct selection remains a challenge. With limited feedback during surgery, it is difficult to verify correct deployment. We propose the use of integrated impedance measurements and Electrical Impedance Tomography (EIT) imaging to assess the deformation of the balloon and determine the size and shape of the surrounding lumen. Previous work using single impedance measurements, or pressure data and analytical models, whilst demonstrating high sizing accuracy, have assumed a circular cross section. Here we extend these methods by adding a multitude of electrodes to detect elliptical and occluded lumen and obtain EIT images to localise deformations. Using a 14 Fr (5.3 mm) catheter as an example, numerical simulations were performed to find the optimal electrode configuration of two rings of 8 electrodes spaced 10 mm apart. The simulations predicted that the maximum detectable aspect ratio decreased from 0.9 for a 14mm balloon to 0.5 at 30mm. The sizing and ellipticity detection results were verified experimentally. A prototype robotic balloon catheter was constructed to automatically inflate a compliant balloon while simultaneously recording EIT and pressure data. Data were collected in experiments replicating stenotic vessels with an elliptical and asymmetrical profile, and the widening of a lumen during angioplasty. After calibration, the system was able to correctly localise the occlusion and detect aspect ratios of 0.75. EIT images further localised the occlusion and visualised the dilation of the lumen during balloon inflation.
Community Contributions
Found the code? Know the venue? Think something is wrong? Let us know!
π Similar Papers
In the same crypt β Robotics
R.I.P.
π»
Ghosted
R.I.P.
π»
Ghosted
AirSim: High-Fidelity Visual and Physical Simulation for Autonomous Vehicles
π
π
The Cartographer
A Survey of Motion Planning and Control Techniques for Self-driving Urban Vehicles
π
π
The Cartographer
Unmanned Aerial Vehicles: A Survey on Civil Applications and Key Research Challenges
π
π
The Cartographer
A Survey of Autonomous Driving: Common Practices and Emerging Technologies
R.I.P.
π»
Ghosted
Learning agile and dynamic motor skills for legged robots
Died the same way β π» Ghosted
R.I.P.
π»
Ghosted
Federated Learning: Strategies for Improving Communication Efficiency
R.I.P.
π»
Ghosted
In-Datacenter Performance Analysis of a Tensor Processing Unit
R.I.P.
π»
Ghosted
Deep Convolutional Neural Networks for Computer-Aided Detection: CNN Architectures, Dataset Characteristics and Transfer Learning
R.I.P.
π»
Ghosted