Eye Tracking for Tele-robotic Surgery: A Comparative Evaluation of Head-worn Solutions
October 18, 2023 Β· Declared Dead Β· π Medical Imaging
"No code URL or promise found in abstract"
Evidence collected by the PWNC Scanner
Authors
Regine BΓΌter, Roger D. Soberanis-Mukul, Paola Ruiz Puentes, Ahmed Ghazi, Jie Ying Wu, Mathias Unberath
arXiv ID
2310.13720
Category
cs.HC: Human-Computer Interaction
Cross-listed
cs.RO
Citations
3
Venue
Medical Imaging
Last Checked
4 months ago
Abstract
Purpose: Metrics derived from eye-gaze-tracking and pupillometry show promise for cognitive load assessment, potentially enhancing training and patient safety through user-specific feedback in tele-robotic surgery. However, current eye-tracking solutions' effectiveness in tele-robotic surgery is uncertain compared to everyday situations due to close-range interactions causing extreme pupil angles and occlusions. To assess the effectiveness of modern eye-gaze-tracking solutions in tele-robotic surgery, we compare the Tobii Pro 3 Glasses and Pupil Labs Core, evaluating their pupil diameter and gaze stability when integrated with the da Vinci Research Kit (dVRK). Methods: The study protocol includes a nine-point gaze calibration followed by pick-and-place task using the dVRK and is repeated three times. After a final calibration, users view a 3x3 grid of AprilTags, focusing on each marker for 10 seconds, to evaluate gaze stability across dVRK-screen positions with the L2-norm. Different gaze calibrations assess calibration's temporal deterioration due to head movements. Pupil diameter stability is evaluated using the FFT from the pupil diameter during the pick-and-place tasks. Users perform this routine with both head-worn eye-tracking systems. Results: Data collected from ten users indicate comparable pupil diameter stability. FFTs of pupil diameters show similar amplitudes in high-frequency components. Tobii Glasses show more temporal gaze stability compared to Pupil Labs, though both eye trackers yield a similar 4cm error in gaze estimation without an outdated calibration. Conclusion: Both eye trackers demonstrate similar stability of the pupil diameter and gaze, when the calibration is not outdated, indicating comparable eye-tracking and pupillometry performance in tele-robotic surgery settings.
Community Contributions
Found the code? Know the venue? Think something is wrong? Let us know!
π Similar Papers
In the same crypt β Human-Computer Interaction
R.I.P.
π»
Ghosted
R.I.P.
π»
Ghosted
Improving fairness in machine learning systems: What do industry practitioners need?
R.I.P.
π»
Ghosted
Identifying Stable Patterns over Time for Emotion Recognition from EEG
R.I.P.
π»
Ghosted
Questioning the AI: Informing Design Practices for Explainable AI User Experiences
R.I.P.
π»
Ghosted
Deep Learning for Sensor-based Human Activity Recognition: Overview, Challenges and Opportunities
R.I.P.
π»
Ghosted
Educational data mining and learning analytics: An updated survey
Died the same way β π» Ghosted
R.I.P.
π»
Ghosted
Federated Learning: Strategies for Improving Communication Efficiency
R.I.P.
π»
Ghosted
In-Datacenter Performance Analysis of a Tensor Processing Unit
R.I.P.
π»
Ghosted
Deep Convolutional Neural Networks for Computer-Aided Detection: CNN Architectures, Dataset Characteristics and Transfer Learning
R.I.P.
π»
Ghosted