An interactive framework for the evaluation and detection of stereoacuity threshold under ambient lighting
June 26, 2024 Β· Declared Dead Β· π arXiv.org
"No code URL or promise found in abstract"
Evidence collected by the PWNC Scanner
Authors
Kritika Lohia, Rijul Saurabh Soans, Rohit Saxena, Tapan Kumar Gandhi
arXiv ID
2406.18336
Category
cs.HC: Human-Computer Interaction
Citations
0
Venue
arXiv.org
Last Checked
5 months ago
Abstract
Objective: Our study aims to provide a novel framework for the continuous evaluation of stereoacuity under ambient lighting conditions using Bayesian inference. Methods: We applied a combination of psychophysical and expected entropy minimization procedures for the computation of a continuous stereoacuity threshold. Subsequently, we evaluated the effect of ambient lighting during stereoacuity testing (ST) by adopting a bisection-matching based adaptive gamma calibration (AGC). Participants ($N=187$) including visually healthy controls ($N=51$), patients with Intermittent Divergent Squint (IDS; $N=45$), and controls with induced anisometropia (IA; $N=91$) performed ST with and without AGC under two lighting conditions: completely dark (20 cd/m$^2$) and normally lit (130 cd/m$^2$) rooms. Results: Our framework demonstrated "excellent" reliability ($> 0.9$) and a positive correlation with TNO (a clinical stereo test), regardless of whether AGC was conducted. However, when AGC is not performed, significant differences (Friedman $X_{r}^{2} = 28.015$; $p<0.00001$; Bland-Altman bias: 30 arc-sec) were found in stereoacuity thresholds between dark and light conditions for participants with IDS and IA. Controls are unaffected by AGC and yield a similar stereoacuity threshold under both lighting conditions. Conclusion: Our study proves that stereoacuity threshold is significantly deviated particularly in participants with IDS or IA stereo-deficits if ambient lighting is not taken into consideration. Moreover, our framework provides a quick (approximately 5-10 minutes) assessment of stereoacuity threshold and can be performed within 30 ST and 15 AGC trials. Significance: Our test is useful in planning treatments and monitoring prognosis for patients with stereo-deficits by accurately assessing stereovision.
Community Contributions
Found the code? Know the venue? Think something is wrong? Let us know!
π Similar Papers
In the same crypt β Human-Computer Interaction
R.I.P.
π»
Ghosted
R.I.P.
π»
Ghosted
Improving fairness in machine learning systems: What do industry practitioners need?
R.I.P.
π»
Ghosted
Identifying Stable Patterns over Time for Emotion Recognition from EEG
R.I.P.
π»
Ghosted
Questioning the AI: Informing Design Practices for Explainable AI User Experiences
R.I.P.
π»
Ghosted
Deep Learning for Sensor-based Human Activity Recognition: Overview, Challenges and Opportunities
R.I.P.
π»
Ghosted
Educational data mining and learning analytics: An updated survey
Died the same way β π» Ghosted
R.I.P.
π»
Ghosted
Federated Learning: Strategies for Improving Communication Efficiency
R.I.P.
π»
Ghosted
In-Datacenter Performance Analysis of a Tensor Processing Unit
R.I.P.
π»
Ghosted
Deep Convolutional Neural Networks for Computer-Aided Detection: CNN Architectures, Dataset Characteristics and Transfer Learning
R.I.P.
π»
Ghosted