Impact of Electrode Position on Forearm Orientation Invariant Hand Gesture Recognition
September 16, 2024 Β· Declared Dead Β· π arXiv.org
"No code URL or promise found in abstract"
Evidence collected by the PWNC Scanner
Authors
Md. Johirul Islam, Umme Rumman, Arifa Ferdousi, Md. Sarwar Pervez, Iffat Ara, Shamim Ahmad, Fahmida Haque, Sawal Hamid, Md. Ali, Kh Shahriya Zaman, Mamun Bin Ibne Reaz, Mustafa Habib Chowdhury, Md. Rezaul Islam
arXiv ID
2410.00029
Category
cs.HC: Human-Computer Interaction
Cross-listed
eess.SP
Citations
2
Venue
arXiv.org
Last Checked
4 months ago
Abstract
Objective: Variation of forearm orientation is one of the crucial factors that drastically degrades the forearm orientation invariant hand gesture recognition performance or the degree of freedom and limits the successful commercialization of myoelectric prosthetic hand or electromyogram (EMG) signal-based human-computer interfacing devices. This study investigates the impact of surface EMG electrode positions (elbow and forearm) on forearm orientation invariant hand gesture recognition. Methods: The study has been performed over 19 intact limbed subjects, considering 12 daily living hand gestures. The quality of the EMG signal is confirmed in terms of three indices. Then, the recognition performance is evaluated and validated by considering three training strategies, six feature extraction methods, and three classifiers. Results: The forearm electrode position provides comparable to or better EMG signal quality considering three indices. In this research, the forearm electrode position achieves up to 5.35% improved forearm orientation invariant hand gesture recognition performance compared to the elbow electrode position. The obtained performance is validated by considering six feature extraction methods, three classifiers, and real-time experiments. In addition, the forearm electrode position shows its robustness with the existence of recent works, considering recognition performance, investigated gestures, the number of channels, the dimensionality of feature space, and the number of subjects. Conclusion: The forearm electrode position can be the best choice for getting improved forearm orientation invariant hand gesture recognition performance. Significance: The performance of myoelectric prosthesis and human-computer interfacing devices can be improved with this optimized electrode position.
Community Contributions
Found the code? Know the venue? Think something is wrong? Let us know!
π Similar Papers
In the same crypt β Human-Computer Interaction
R.I.P.
π»
Ghosted
R.I.P.
π»
Ghosted
Improving fairness in machine learning systems: What do industry practitioners need?
R.I.P.
π»
Ghosted
Identifying Stable Patterns over Time for Emotion Recognition from EEG
R.I.P.
π»
Ghosted
Questioning the AI: Informing Design Practices for Explainable AI User Experiences
R.I.P.
π»
Ghosted
Deep Learning for Sensor-based Human Activity Recognition: Overview, Challenges and Opportunities
R.I.P.
π»
Ghosted
Educational data mining and learning analytics: An updated survey
Died the same way β π» Ghosted
R.I.P.
π»
Ghosted
Federated Learning: Strategies for Improving Communication Efficiency
R.I.P.
π»
Ghosted
In-Datacenter Performance Analysis of a Tensor Processing Unit
R.I.P.
π»
Ghosted
Deep Convolutional Neural Networks for Computer-Aided Detection: CNN Architectures, Dataset Characteristics and Transfer Learning
R.I.P.
π»
Ghosted