Improving Deformable Image Registration Accuracy through a Hybrid Similarity Metric and CycleGAN Based Auto-Segmentation
November 25, 2024 Β· Declared Dead Β· π arXiv.org
"No code URL or promise found in abstract"
Evidence collected by the PWNC Scanner
Authors
Keyur D. Shah, James A. Shackleford, Nagarajan Kandasamy, Gregory C. Sharp
arXiv ID
2411.16992
Category
physics.med-ph
Cross-listed
cs.CV
Citations
3
Venue
arXiv.org
Last Checked
3 months ago
Abstract
Purpose: Deformable image registration (DIR) is critical in adaptive radiation therapy (ART) to account for anatomical changes. Conventional intensity-based DIR methods often fail when image intensities differ. This study evaluates a hybrid similarity metric combining intensity and structural information, leveraging CycleGAN-based intensity correction and auto-segmentation across three DIR workflows. Methods: A hybrid similarity metric combining a point-to-distance (PD) score and intensity similarity was implemented. Synthetic CT (sCT) images were generated using a 2D CycleGAN model trained on unpaired CT and CBCT images to enhance soft-tissue contrast. DIR workflows compared included: (1) traditional intensity-based (No PD), (2) auto-segmented contours on sCT (CycleGAN PD), and (3) expert manual contours (Expert PD). A 3D U-Net model trained on 56 images and validated on 14 cases segmented the prostate, bladder, and rectum. DIR accuracy was assessed using Dice Similarity Coefficient (DSC), 95% Hausdorff Distance (HD), and fiducial separation. Results: The hybrid metric improved DIR accuracy. For the prostate, DSC increased from 0.61+/-0.18 (No PD) to 0.82+/-0.13 (CycleGAN PD) and 0.89+/-0.05 (Expert PD), with reductions in 95% HD from 11.75 mm to 4.86 mm and 3.27 mm, respectively. Fiducial separation decreased from 8.95 mm to 4.07 mm (CycleGAN PD) and 4.11 mm (Expert PD) (p < 0.05). Improvements were also observed for the bladder and rectum. Conclusion: This study demonstrates that a hybrid similarity metric using CycleGAN-based auto-segmentation improves DIR accuracy, particularly for low-contrast CBCT images. These findings highlight the potential for integrating AI-based image correction and segmentation into ART workflows to enhance precision and streamline clinical processes.
Community Contributions
Found the code? Know the venue? Think something is wrong? Let us know!
π Similar Papers
In the same crypt β physics.med-ph
R.I.P.
π»
Ghosted
R.I.P.
π»
Ghosted
Gibbs-Ringing Artifact Removal Based on Local Subvoxel-shifts
R.I.P.
π»
Ghosted
Deep Learning-enabled Virtual Histological Staining of Biological Samples
R.I.P.
π»
Ghosted
Eigenspectra optoacoustic tomography achieves quantitative blood oxygenation imaging deep in tissues
π
π
The Cartographer
Deep learning for biomedical photoacoustic imaging: A review
R.I.P.
π»
Ghosted
The reliability of a deep learning model in clinical out-of-distribution MRI data: a multicohort study
Died the same way β π» Ghosted
R.I.P.
π»
Ghosted
Neural Architecture Search with Reinforcement Learning
R.I.P.
π»
Ghosted
Federated Learning: Strategies for Improving Communication Efficiency
R.I.P.
π»
Ghosted
In-Datacenter Performance Analysis of a Tensor Processing Unit
R.I.P.
π»
Ghosted