Improving Deformable Image Registration Accuracy through a Hybrid Similarity Metric and CycleGAN Based Auto-Segmentation

November 25, 2024 Β· Declared Dead Β· πŸ› arXiv.org

πŸ‘» CAUSE OF DEATH: Ghosted
No code link whatsoever

"No code URL or promise found in abstract"

Evidence collected by the PWNC Scanner

Authors Keyur D. Shah, James A. Shackleford, Nagarajan Kandasamy, Gregory C. Sharp arXiv ID 2411.16992 Category physics.med-ph Cross-listed cs.CV Citations 3 Venue arXiv.org Last Checked 3 months ago
Abstract
Purpose: Deformable image registration (DIR) is critical in adaptive radiation therapy (ART) to account for anatomical changes. Conventional intensity-based DIR methods often fail when image intensities differ. This study evaluates a hybrid similarity metric combining intensity and structural information, leveraging CycleGAN-based intensity correction and auto-segmentation across three DIR workflows. Methods: A hybrid similarity metric combining a point-to-distance (PD) score and intensity similarity was implemented. Synthetic CT (sCT) images were generated using a 2D CycleGAN model trained on unpaired CT and CBCT images to enhance soft-tissue contrast. DIR workflows compared included: (1) traditional intensity-based (No PD), (2) auto-segmented contours on sCT (CycleGAN PD), and (3) expert manual contours (Expert PD). A 3D U-Net model trained on 56 images and validated on 14 cases segmented the prostate, bladder, and rectum. DIR accuracy was assessed using Dice Similarity Coefficient (DSC), 95% Hausdorff Distance (HD), and fiducial separation. Results: The hybrid metric improved DIR accuracy. For the prostate, DSC increased from 0.61+/-0.18 (No PD) to 0.82+/-0.13 (CycleGAN PD) and 0.89+/-0.05 (Expert PD), with reductions in 95% HD from 11.75 mm to 4.86 mm and 3.27 mm, respectively. Fiducial separation decreased from 8.95 mm to 4.07 mm (CycleGAN PD) and 4.11 mm (Expert PD) (p < 0.05). Improvements were also observed for the bladder and rectum. Conclusion: This study demonstrates that a hybrid similarity metric using CycleGAN-based auto-segmentation improves DIR accuracy, particularly for low-contrast CBCT images. These findings highlight the potential for integrating AI-based image correction and segmentation into ART workflows to enhance precision and streamline clinical processes.
Community shame:
Not yet rated
Community Contributions

Found the code? Know the venue? Think something is wrong? Let us know!

πŸ“œ Similar Papers

In the same crypt β€” physics.med-ph

Died the same way β€” πŸ‘» Ghosted