Leveraging Foundation Models for Calibration-Free c-VEP BCIs
November 04, 2025 Β· Declared Dead Β· π IEEE International Conference on Systems, Man and Cybernetics
"No code URL or promise found in abstract"
Evidence collected by the PWNC Scanner
Authors
Mohammadreza Behboodi, Eli Kinney-Lang, Ali Etemad, Adam Kirton, Hatem Abou-Zeid
arXiv ID
2601.06028
Category
cs.HC: Human-Computer Interaction
Cross-listed
cs.LG
Citations
0
Venue
IEEE International Conference on Systems, Man and Cybernetics
Last Checked
4 months ago
Abstract
Foundation Models (FMs) have surged in popularity over the past five years, with applications spanning fields from computer vision to natural language processing. Brain-Computer Interfaces (BCIs) have also gained momentum due to their potential to support individuals with complex disabilities. Among BCI paradigms, code-modulated Visual Evoked Potentials (c-VEPs) remain relatively understudied, despite offering high information transfer rates and large selection target capacities. However, c-VEP systems require lengthy calibration sessions, limiting their practicality outside of laboratory settings. In this study, we use a FM for the first time to eliminate the need for lengthy calibration in c-VEP BCI systems. We evaluated two approaches: (1) a truly calibration-free approach requiring no subject-specific data, and (2) a limited calibration approach, where we assessed the benefit of incorporating incremental amounts of calibration data. In both cases, a classification head is trained on data from other subjects. For a new subject, no calibration data is required in the calibration-free setup, making the c-VEP system effectively plug-and-play. The proposed method was tested on two c-VEP datasets. For the calibration-free approach, the average accuracy on the first dataset (n = 17) was 68.8% +/- 17.6%, comparable to the full-calibration performance reported in the original study (66.2% +/- 13.8%), which required approximately 11 minutes of calibration. On the second dataset (n = 12), the calibration-free accuracy was 71.8% +/- 20.2%, versus 93.7% +/- 5.5% from the original study, which required around 3.5 minutes. A limited-calibration approach using only 20% of the subject's data (approximately 43 seconds) yielded 92% +/- 5.2% accuracy. These results indicate that our FM-based approach can effectively eliminate or significantly reduce the need for lengthy calibration in c-VEP BCIs.
Community Contributions
Found the code? Know the venue? Think something is wrong? Let us know!
π Similar Papers
In the same crypt β Human-Computer Interaction
R.I.P.
π»
Ghosted
R.I.P.
π»
Ghosted
Improving fairness in machine learning systems: What do industry practitioners need?
R.I.P.
π»
Ghosted
Identifying Stable Patterns over Time for Emotion Recognition from EEG
R.I.P.
π»
Ghosted
Questioning the AI: Informing Design Practices for Explainable AI User Experiences
R.I.P.
π»
Ghosted
Deep Learning for Sensor-based Human Activity Recognition: Overview, Challenges and Opportunities
R.I.P.
π»
Ghosted
Educational data mining and learning analytics: An updated survey
Died the same way β π» Ghosted
R.I.P.
π»
Ghosted
Federated Learning: Strategies for Improving Communication Efficiency
R.I.P.
π»
Ghosted
In-Datacenter Performance Analysis of a Tensor Processing Unit
R.I.P.
π»
Ghosted
Deep Convolutional Neural Networks for Computer-Aided Detection: CNN Architectures, Dataset Characteristics and Transfer Learning
R.I.P.
π»
Ghosted