CDSA-Net:Collaborative Decoupling of Vascular Structure and Background for High-Fidelity Coronary Digital Subtraction Angiography

April 19, 2026 ยท Grace Period ยท + Add venue

โณ Grace Period
This paper is less than 90 days old. We give authors time to release their code before passing judgment.
Authors Si Li, Chen-Kai Hu, Zhenhuan Lyu, Yuanqing He arXiv ID 2604.17208 Category cs.CV: Computer Vision Cross-listed cs.AI Citations 0
Abstract
Digital subtraction angiography (DSA) in coronary imaging is fundamentally challenged by physiological motion, forcing reliance on raw angiograms cluttered with anatomical noise. Existing deep learning methods often produced images with two critical clinically unacceptable flaws: persistent boundary artifacts and a loss of native tissue grayscale fidelity that undermined diagnostic confidence. We propose a novel framework termed as CDSA-Net that for the first time explicitly decouples and jointly optimizes vascular structure preservation and realistic background restoration. CDSA-Net introduces two core innovations: (i) A hierarchical geometric prior guidance (HGPG) mechanism, embedded in our coronary structure extraction network (CSENet). It synergistically combines integrated geometric prior (IGP) with gated spatial modulation (GSM) and centerline-aware topology (CAT) loss supervision, ensuring structural continuity. (ii) An adaptive noise module (ANM) within our coronary background restoration network (CBResNet). Unlike standard restoration, ANM uniquely models the stochastic nature of clinical X-ray noise, bridging the domain gap to enable seamless background intensity estimation and the complete elimination of boundary artifacts. The final subtraction is obtained by removing the restored background from the raw angiogram. Quantitatively, it significantly outperformed state-of-the-art methods in vascular intensity correlation and perceptual quality. A 25.6% improvement in morphology assessment efficiency and a 42.9% gain in hemodynamic evaluation speed set a new benchmark for utility in interventional cardiology, while maintaining diagnostic results consistent with raw angiograms. The project code is available at https://github.com/DrThink-ai/CDSA-Net.
Community shame:
Not yet rated
Community Contributions

Found the code? Know the venue? Think something is wrong? Let us know!

๐Ÿ“œ Similar Papers

In the same crypt โ€” Computer Vision

๐ŸŒ… ๐ŸŒ… Old Age

Fast R-CNN

Ross Girshick

cs.CV ๐Ÿ› ICCV ๐Ÿ“š 27.7K cites 11 years ago