Does FLAIR super-resolution erase or hallucinate small white-matter lesions?

August 06, 2026 ยท Grace Period ยท ๐Ÿ› MICCAI 2026

โณ Grace Period
This paper is less than 90 days old. We give authors time to release their code before passing judgment.
Authors Zahra Khodakarami, Yue Li, Pulkit Khandelwal, John Detre, Sandhitsu Das, Christopher Brown, David Wolk, Paul Yushkevich arXiv ID 2608.06311 Category cs.CV: Computer Vision Cross-listed cs.AI Citations 0 Venue MICCAI 2026
Abstract
White matter hyperintensities (WMH), bright regions on Fluid-attenuated Inversion Recovery (FLAIR) scans are associated with cerebrovascular pathology and neurodegeneration. FLAIR is usually acquired with thick slices in clinical settings, giving it poor through-plane resolution. Super-resolution (SR) is a widely used method for recovering an isotropic volume from an anisotropic scan. Yet whether applying it prior to WMH segmentation preserves lesion content remains unknown: a model may erase small real lesions or hallucinate absent ones. We used 1-mm isotropic high-resolution (HR) FLAIR scans from 29 individuals in the ADNI cohort, each manually segmented for WMH by an expert. Then, we degraded each to simulated 3 and 5 mm through-plane acquisitions. Multi-contrast implicit neural representation (INR), a single-contrast self-supervised model (ECLARE), and cubic interpolation were used to upsample them onto the HR grid. WMH segmentation from a simulated thick slice and the original HR FLAIR set the floor and ceiling, respectively, for the per-lesion analysis. Of four WMH segmentation methods (WMH-SynthSeg, segcsvd, MARS-WMH, TrUE-Net), we ran the analysis under the most sensitive one to small lesions on HR (MARS-WMH) with the evaluation metrics of detection sensitivity, erasure rate (HR-detected lesions lost after reconstruction), and hallucination rate (predicted components absent from both the manual and HR segmentation). The dominant effect of SR was erasure of small real lesions, not hallucination, and it increased with slice thickness, though every reconstruction still improved lesion detection over the raw thick slice. ECLARE recovered small lesion signal best at both thicknesses, while the INR was no better than cubic interpolation.
Community shame:
Not yet rated
Community Contributions

Found the code? Know the venue? Think something is wrong? Let us know!

๐Ÿ“œ Similar Papers

In the same crypt โ€” Computer Vision

๐ŸŒ… ๐ŸŒ… Old Age

Fast R-CNN

Ross Girshick

cs.CV ๐Ÿ› ICCV ๐Ÿ“š 27.7K cites 11 years ago