Task-Adaptive 3D Cross-Field MRI Translation via Field-Conditioned Content-Style Pretraining

August 10, 2026 ยท Grace Period ยท ๐Ÿ› MICCAI 2026 Workshop

โณ Grace Period
This paper is less than 90 days old. We give authors time to release their code before passing judgment.
Authors Haowen Pang, Yingqi Hao, Pengli Zhu arXiv ID 2608.09264 Category cs.CV: Computer Vision Citations 0 Venue MICCAI 2026 Workshop
Abstract
Magnetic field strength is a major source of domain shift in magnetic resonance imaging (MRI), affecting signal-to-noise ratio, tissue contrast, spatial detail, and the visibility of anatomical boundaries. The MRIxFields 2026 challenge investigates this problem through cross-field MRI translation across acquisitions at 0.1T, 1.5T, 3T, 5T, and 7T. Its three tasks, Any-to-7T, 0.1T-to-High, and Any-to-Any synthesis, require the generation of target-field image characteristics while preserving subject-specific anatomy. This problem is particularly challenging because paired acquisitions of the same subject across multiple field strengths are rarely available for training. We propose a 3D unpaired cross-field MRI translation framework based on field-conditioned content-style pretraining. The proposed framework first learns controllable field-to-field translation across all available field strengths by disentangling anatomical content from field-dependent contrast characteristics. The pretrained backbone is then adapted to task-specific target domains. Our model comprises a 3D content encoder, a 3D style encoder, a field-conditioned style generator, an AdaIN-modulated decoder, and a multi-field discriminator. Adversarial learning encourages realistic target-field appearance, while cycle-consistency, identity, content, style, and diversity constraints promote anatomical fidelity and controllable translation. We evaluate the proposed method on MRIxFields data spanning five field strengths and three MRI modalities. Experiments on paired test data demonstrate that the framework can adapt to the three challenge settings while preserving three-dimensional anatomical structure in the synthesized volumes. The implementation code is publicly available at https://github.com/Idea89560041/3D-MRI-Field-Translation.
Community shame:
Not yet rated
Community Contributions

Found the code? Know the venue? Think something is wrong? Let us know!

๐Ÿ“œ Similar Papers

In the same crypt โ€” Computer Vision

๐ŸŒ… ๐ŸŒ… Old Age

Fast R-CNN

Ross Girshick

cs.CV ๐Ÿ› ICCV ๐Ÿ“š 27.7K cites 11 years ago